Potential of multivariate statistical process monitoring based on the biogas composition to detect free ammonia intoxication in anaerobic reactors

Lemaigre, Sébastien;Adam, Gilles;Gerin, Patrick;Noo, Anaïs;Delfosse, Philippe;et.al.
(2018) Biochemical Engineering Journal — Vol. 140, p. 17-28 (2018)

Files

Lemaigreetal2018.pdf
  • Open Access
  • Adobe PDF
  • 2.93 MB

Details

Authors
  • Lemaigre, SébastienUCLouvain
    Author
  • Adam, GillesEnvironmental Research and Innovation Department (ERIN), Luxembourg Institute of Science and Technology (LIST), Rue du Brill 41, L-4422 Belvaux, Luxembourg
    Author
  • Author
  • Noo, AnaïsEnvironmental Research and Innovation Department (ERIN), Luxembourg Institute of Science and Technology (LIST), Rue du Brill 41, L-4422 Belvaux, Luxembourg
    Author
  • Delfosse, PhilippeEnvironmental Research and Innovation Department (ERIN), Luxembourg Institute of Science and Technology (LIST), Rue du Brill 41, L-4422 Belvaux, Luxembourg
    Author
Show more
Abstract
Three anaerobic digestion reactors were initially maintained at steady-state with low nitrogen input, then progressively exposed to increasing nitrogen input until extreme ammonia intoxication, leading to interruption of biogas production. Such interruption occurred for a free ammonia nitrogen (FAN) concentration of about 5 g Lslurry−1. A fourth reactor used as a control was maintained at low nitrogen steady-state. The biogas composition (CH4, CO2, H2 and H2S) was recorded over time and data were fed into a multivariate statistical process control model based on principal components analysis (PCA-MSPC). Static PCA-MSPC failed to distinguish between the actual reactor performance decrease and the drift of the in-control process baseline. However, recursively updated PCA-MSPC (effective memory length of 14 days, i.e. 0.25 hydraulic retention time) allowed detection of the early signs of FAN induced process dysfunction, which were simultaneous with drastic changes in the microbiome of the replicate reactors. However, the process control model was not able to adapt to a drastic modification of the microbiome. Propionate continuously accumulated since the detection of the first signs of process dysfunction.
Affiliations

Citations

Lemaigre, S., Adam, G., Gerin, P., Noo, A., De Vos, B., Klimek, D., Goux, X., Calusinska, M., & Delfosse, P. (2018). Potential of multivariate statistical process monitoring based on the biogas composition to detect free ammonia intoxication in anaerobic reactors. Biochemical Engineering Journal, 140, 17-28. https://doi.org/10.1016/j.bej.2018.08.018 (Original work published 2018)