(2016) Journal of Loss Prevention in the Process Industries : the international journal of chemical and process plant safety — Vol. 43, p. 83-91 (2016)
Triboelectric charging of powders during pneumatic transport can lead to hazardous spark discharges. In this study, the charging process was studied numerically by means of large eddy simulations. A range of design parameters was then analyzed statistically applying the design of experiments methodology. It is shown that the electric charge of the powder can be significantly decreased by reducing the conveying air velocity. Furthermore, the usage of pipes of a larger diameter and the application of higher solid mass flow rates also reduce the powder charge.
Grosshans, H., & Papalexandris, M. (2016). Evaluation of the parameters influencing electrostatic charging of powder in a pipe flow. Journal of Loss Prevention in the Process Industries : the international journal of chemical and process plant safety, 43, 83-91. https://doi.org/10.1016/j.jlp.2016.05.002 (Original work published 2016)