Shielding studies for a hadron therapy center

Stichelbaut, Frederic;Canon, T.;Jongen, Yves
(2009) Nuclear Technology — Vol. 168, n° 2, p. 477-481 (2009)

Files

No attached file found for this publication.

Details

Authors
  • Stichelbaut, FredericUCLouvain
    Author
  • Canon, T.
    Author
  • Jongen, YvesUCLouvain
    Author
Abstract
The Ion Beam Applications Company is developing a compact superconducting cyclotron for hadron therapy. This C400 cyclotron will deliver 400 MeV per nucleon 12 C beams and will be installed in the Advanced Resource Center for Hadrontherapy in Europe in Caen, France. Shielding studies are based on the Particle and Heavy Ion Transport code System (PHITS) to compute the secondary neutron sources and MCNPX for the transport of these neutrons inside the facility.
Affiliations

Citations

Stichelbaut, F., Canon, T., & Jongen, Y. (2009). Shielding studies for a hadron therapy center. Nuclear Technology, 168(2), 477-481. https://hdl.handle.net/2078.5/148660 (Original work published 2009)