Design study of a 17.3 GHz electron cyclotron resonance (ECR) ion source at Louvain-la-NeuveStandaert, L.;Davin, F.;Loiselet, M.(2014) Review of Scientific Instruments — Vol. 85, n° 2 (2014)
FilesNo attached file found for this publication.DetailsAuthorsStandaert, L.AuthorDavin, F.AuthorLoiselet, M.AuthorAbstractThe Cyclotron Resources Center of the Louvain-la-Neuve University is developing a new electron cyclotron resonance ion source to increase the energy of the accelerated beam by injection of higher charge state ions into the cyclotron. The design of the source is based on a 17.3 GHz frequency and classical coils to produce the axial field. The field reaches 2 T at the injection side and 1.2 T at extraction. The total power consumption for the coils is limited to 80 kW. The design features of the source are presented. © 2014 AIP Publishing LLC.Show moreCitations APA Chicago FWB Standaert, L., Davin, F., & Loiselet, M. (2014). Design study of a 17.3 GHz electron cyclotron resonance (ECR) ion source at Louvain-la-Neuve. Review of Scientific Instruments, 85(2). https://doi.org/10.1063/1.4857995 (Original work published 2014)