DEAR EDITORS, We previously reported on the biological variation of the thrombin generation assay (TGA) with and without thrombomodulin (TM) using a calibrated automated thrombogram (CAT) system.1 Recently, the ST Genesia (Diagnostica Stago, Asnières sur Seine, France), a fully automated thrombin generation system, was launched with the aim of standardizing TGA by reducing inter-experiment and inter-laboratory variation. This study therefore aimed to determine the biological variation of TGA on this automated platform. [...]
van Dievoet, M.-A., Morimont, L., Bouvy, C., Gruson, D., Stephenne, X., & Douxfils, J. (2024). Biological variation of thrombin generation on ST Genesia. International Journal of Laboratory Hematology, 46(3), 564-567. https://doi.org/10.1111/ijlh.14232 (Original work published 2024)