Attenuation-corrected 99mTc-MIBI SPECT in overweight patients with chronic ischaemic dysfunction: a comparison to NH3 PET and implications for the diagnosis of myocardial viability.

Roelants, Véronique;Bernard, Xavier;Walrand, Stéphan;Bol, Anne;Vanoverschelde, Jean-Louis;et.al.
(2006) Nuclear Medicine Communications — Vol. 27, n° 10, p. 815-821 (2006)

Files

NuclMedCommun200627815-821.pdf
  • Restricted Access
  • Adobe PDF
  • 96.25 KB

Details

Authors
Show more
Abstract
OBJECTIVE: We determined the value of attenuation correction (AC) of myocardial perfusion estimation with (99m)Tc-MIBI SPECT in overweight patients by comparison of uncorrected (filtered back-projection (FBP) and corrected (an iterative algorithm with a measured attenuation coefficients map (FL-AC)) (99m)Tc-MIBI relative uptake to perfusion data obtained in the same patients with NH3 PET. In addition, the impact of attenuation correction for the assessment of myocardial viability with (99m)Tc-MIBI SPECT was determined using FDG PET as the reference method. METHODS: Thirty consecutive overweight patients (BMI=28+/-4) with left ventricular dysfunction underwent a resting (99m)Tc-MIBI SPECT and a PET study (NH3 and FDG). (99m)Tc-MIBI SPECT scans were reconstructed without attenuation correction (FBP) and with attenuation correction (FL-AC). The left ventricle was divided into 16 segments, in which the relative uptake was quantified using circumferential profiles. A relative uptake > or = 60% was considered consistent with viable myocardium for FDG and MIBI. RESULTS: The absolute difference between (99m)Tc-MIBI SPECT and NH3 PET uptakes was less pronounced in the inferior (12+/-10% vs. 17+/-12%, P<0.001), anteroseptal (12+/-11% vs. 16+/-12%, P=0.009) and septal (15+/-12% vs. 18+/-14%, P=0.003) regions (FL-AC vs. FBP, respectively). The sensitivity of MIBI for diagnosing myocardial viability increased from 83 to 100% (P=0.034), without loss in specificity. CONCLUSION: Attenuation correction improves myocardial perfusion estimation by (99m)Tc-MIBI SPECT in the inferior, anteroseptal and septal regions and increases its sensitivity for the diagnosis of myocardial viability.
Affiliations

Citations

Roelants, V., Bernard, X., Walrand, S., Bol, A., Coppens, A., Jamar, F., Melin, J., & Vanoverschelde, J.-L. (2006). Attenuation-corrected 99mTc-MIBI SPECT in overweight patients with chronic ischaemic dysfunction: a comparison to NH3 PET and implications for the diagnosis of myocardial viability. Nuclear Medicine Communications, 27(10), 815-821. https://doi.org/10.1097/01.mnm.0000237985.23973.fb (Original work published 2006)