Validation of echocardiography for measuring cardiac output by the multiple gas elimination technique

Rennotte, Marie-Thérèse;Vanoverschelde, Jean-Louis;Robert, Annie;Dion, R.;Frans, Albert;et.al.
(1998) Pathologie et Biologie — Vol. 46, n° 8, p. 591-596 (1998)

Files

No attached file found for this publication.

Details

Authors
  • Rennotte, Marie-ThérèseUCLouvain
    Author
  • Vanoverschelde, Jean-LouisUCLouvain
    Author
  • Robert, AnnieUCLouvain
    Author
  • Dion, R.
    Author
  • Clerbaux, ThierryUCLouvain
    Author
  • Frans, AlbertUCLouvain
    Author
Show more
Abstract
The multiple inert gas elimination technique (MIGET) is being increasingly used in respiratory physiology and pathophysiology. Six inert gases are given as an intravenous infusion then measured in samples of expired air and mixed arterial and venous blood. This requires right-sided catheterization, a procedure that is sometimes ethically inappropriate. The present article reports a method in which inert gas levels in mixed venous blood were calculated, rather than measured, using Fick's law. Echocardiography was used to measure arterial inert gas levels and cardiac output. The method was validated in 11 men scheduled to undergo coronary bypass surgery. Cardiac output was either calculated based on biometrical (C) data or measured using four different methods in random order, namely Fick's law with oxygen (FiO(2)) or the inert gases (FiIG) as the tracers, thermodilution (TH), and echocardiography (E). Cardiac output values in L.min(-1) ((X) over bar +/- SD) were as follows : C, 4.99 +/- 0.39; FiO(2), 5.44 +/- 0.86; FiIG, 5.55 +/- 0.92; TH, 5.77 +/- 0.88; and E, 5.53 +/- 0.64. No significant differences were found among the four measured cardiac output values, of which the mean was 5.57 +/- 0.70 L/min, a value that was significantly higher than the calculated value. This difference is probably ascribable to the use of dopamine, dobutamine, or epinephrine in six of the 11 patients. A 1 L/min(-1) cardiac output error, in either direction, was found to have a merited influence on the distribution of alveolar perfusion at various (V) over dot A/(Q) over dot ratios. Conversely, as expected, ventilation distribution was not influenced by cardiac output. In conclusion, echocardiography provides satisfactory cardiac output estimations using the MIGET except in patients with septal hypertrophy, subaortic membranes, a mitral valve prosthesis, or a mitral valve ring.
Affiliations

Citations

Rennotte, M.-T., Vanoverschelde, J.-L., Robert, A., Dion, R., Clerbaux, T., Veriter, C., & Frans, A. (1998). Validation of echocardiography for measuring cardiac output by the multiple gas elimination technique. Pathologie et Biologie, 46(8), 591-596. https://hdl.handle.net/2078.5/141348 (Original work published 1998)