Quantitative Xps .2. Comparison Between Different Quantitative Approaches for 2 Different Spectrometers - Determination of the Contamination-reduced Thickness, Application of the Determined Transmission Functions and Accuracy Achieved

Weng, LT.;Vereecke, G.;Genet, MJ.;Rouxhet, Paul;Stone, WEE.;et.al.
(1993) Surface and Interface Analysis — Vol. 20, n° 3, p. 193-205 (1993)

Files

No attached file found for this publication.

Details

Authors
  • Weng, LT.
    Author
  • Vereecke, G.
    Author
  • Genet, MJ.
    Author
  • Rouxhet, PaulUCLouvain
    Author
  • Bertrand, PatrickUCLouvain
    Author
  • Stone, WEE.
    Author
Show more
Abstract
The first principles model (FPM) has been compared with other quantitative approaches by using many standard samples. As a first step, the applicability of the theoretical dependence of I(C1s)/I(C KVV) on the reduced thickness (x) of a hydrocarbon surface contamination layer was checked and shown to be approximately correct only in the middle range of x. A semi-empirical relation between I(C 1s)/I(C KVV) and x has been developed. The advantage of this relation over that previously developed in the literature is that the transmission function of our spectrometer is well characterized. The reduced thickness calculated using this semi-empirical relation has been shown to be close to the real value. The comparison of atomic ratios calculated using these quantitative approaches has shown that the best approach is the FPM. For the samples investigated in this work, the introduction of the anisotropy parameter L is not necessary: in most cases, the influence of L is smaller than the observed errors; and in certain cases where the difference of L values is large, more consistent results are obtained when L is ignored. The FPM approach provides consistent results not only when an inter-comparison is made between different spectrometers but also when, within a given machine, the analysis conditions are varied. The accuracy of this approach is relatively good (with errors < 15%) and holds true even when comparing peaks separated by more than 1000 eV. Finally, the comparison of results obtained with different previously determined transmission functions has allowed us to test the applicability of the methods used for the determination of these transmission functions (see Part I).
Affiliations

Citations

Weng, LT., Vereecke, G., Genet, MJ., Rouxhet, P., Stonemasui, JH., Bertrand, P., & Stone, WEE. (1993). Quantitative Xps .2. Comparison Between Different Quantitative Approaches for 2 Different Spectrometers - Determination of the Contamination-reduced Thickness, Application of the Determined Transmission Functions and Accuracy Achieved. Surface and Interface Analysis, 20(3), 193-205. https://doi.org/10.1002/sia.740200303 (Original work published 1993)