Beam test results on double-gap resistive plate chambers proposed for CMS experiment

Abbrescia, M.;Bruno, Giacomo;et.al.
(1998) Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment — Vol. 414, n° 2-3, p. 135-148 (1998)

Files

1-s20-S0168900298005713-main.pdf
  • Open Access
  • Adobe PDF
  • 357.01 KB

Details

Authors
Abstract
Resistive Plate Chambers were tested in a muon and pion beam to study the performances at different running conditions. Results on a first chamber built without the linseed oil treatment of the bakelite surfaces are presented together with an evaluation of the local effects due to the spacers. These results are extrapolated to the conditions expected at LHC.
Affiliations

Citations

Abbrescia, M., Bruno, G., & et al. (1998). Beam test results on double-gap resistive plate chambers proposed for CMS experiment. Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment, 414(2-3), 135-148. https://doi.org/10.1016/S0168-9002(98)00571-3 (Original work published 1998)