Relative biological effectiveness (RBE) and oxygen enhancement ratio (OER) values of different neutron beams produced at the variable energy cyclotron "Cyclone" of Louvain-la-Neuve (Belgium) were determined. The neutrons were obtained by bombarding a beryllium target with 34-, 45-, 65-, or 75-MeV protons or with 50-MeV deuterons. The biological system was growth inhibition in Vicia faba bean roots. Taking the p(65) + Be neutron beam as a reference, RBE values were found equal to 1.36 +/- 0.2, 1.20 +/- 0.1, 1.00 (ref), 0.98 +/- 0.1, and 1.18 +/- 0.1, respectively; the doses corresponding to 50% growth inhibition were 0.39, 0.44, 0.53, 0.54, and 0.45 Gy. For the same beams, OER values were found equal to 1.55 +/- 0.1, 1.38 +/- 0.1, 1.29 +/- 0.1, 1.41 +/- 0.1, and 1.60 +/- 0.2, respectively.
Beauduin, M., Vynckier, S., Gueulette, J., & Wambersie, A. (1989). Radiobiological intercomparison of clinical neutron beams for growth inhibition in Vicia faba bean roots. Radiation Research : an international journal, 117(2), 245-250. https://doi.org/10.2307/3577325 (Original work published 1989)