Evaluation of technetium-99m-L,L-EC in renal transplant recipients: a comparative study with technetium-99m-MAG3 and iodine-125-OIH

Stoffel, Michel;Jamar, François;Van Nerom, Chris;Verbruggen, Alfons;Beckers, Christian;et.al.
(1994) The Journal of Nuclear Medicine — Vol. 35, n° 12, p. 1951-1958 (1994)

Files

13396.pdf
  • Restricted Access
  • Adobe PDF
  • 1.34 MB

Details

Authors
  • Stoffel, MichelUCLouvain
    Author
  • Author
  • Van Nerom, ChrisUCLouvain
    Author
  • Verbruggen, AlfonsUCLouvain
    Author
  • Mourad, MichelUCLouvain
    Author
  • Leners, NorbertUCLouvain
    Author
  • Squifflet, Jean-PaulUCLouvain
    Author
  • Beckers, ChristianUCLouvain
    Author
Show more
Abstract
The clinical usefulness of kit-formulated 99mTc-L,L-EC, a new renal tubular tracer agent based on a diaminodithiol ligand was evaluated in a large population of renal transplant recipients. METHODS: Fifty patients with transplants were studied. Five patients with renal insufficiency and five normal volunteers were also included to extend the range of renal function values. The labeling efficiency of 99mTc-L,L-EC in routine conditions, i.e., without HPLC purification, and the safety of the tracer were evaluated. RESULTS: The mean radiochemical purity of 99mTc-L,L-EC determined by thin-layer chromatography was 97.4%. No side effects or significant biochemical changes were observed. The clearance of 99mTc-L,L-EC and 125I-OIH ranged from 10.7 to 417.5 and from 27.6 to 602.7 ml/min/1.73 m2, respectively. The clearance of 99mTc-L,L-EC and 99mTc-MAG3 averaged respectively 71% and 52% of that of 125I-OIH. CONCLUSION: The labeling procedure of kit-formulated 99mTc-L,L-EC is easy and efficient. This tracer is safe and suitable for both imaging and quantitative measurement of the renal tubular function. Technetium-99m-L,L-EC represents an excellent alternative to 99mTc-MAG3.
Affiliations

Citations

Stoffel, M., Jamar, F., Van Nerom, C., Verbruggen, A., Mourad, M., Leners, N., Squifflet, J.-P., & Beckers, C. (1994). Evaluation of technetium-99m-L,L-EC in renal transplant recipients: a comparative study with technetium-99m-MAG3 and iodine-125-OIH. The Journal of Nuclear Medicine, 35(12), 1951-1958. https://hdl.handle.net/2078.5/137153 (Original work published 1994)