Résultats préliminaires du traitement du décollement de rétine rhegmatogène par un nouveau matériel d'indentation épisclérale: l'éponge siliconée et biseautée de Korobelnik.

Gribomont, Anne-Catherine
(2003) Bulletin de la Société belge d’ophtalmologie — n° 287, p. 73-75 (2003)

Files

26720.pdf
  • Restricted Access
  • Adobe PDF
  • 37.05 KB

Details

Authors
  • Gribomont, Anne-CatherineUCLouvain
    Author
Abstract
In order to evaluate the efficacy and short-term tolerance of the Korobelnik sponge in the primary treatment of uncomplicated rhegmatogenous retinal detachments (RRD), a retrospective study dealing with the first 30 consecutive cases of RRD primarily operated on with the use of this Korobelnik sponge is undertaken. Primary anatomical success is obtained in 80% of the cases (24/30), with a mean postoperative follow-up of 3.1 months. Conjunctival inflammation or dehiscence are not observed. Two sponges have to be removed for unrelated reasons. The study shows that the Korobelnik sponge is a reliable and well-tolerated buckling material, at least in the short term.
Affiliations

Citations

Gribomont, A.-C. (2003). Résultats préliminaires du traitement du décollement de rétine rhegmatogène par un nouveau matériel d’indentation épisclérale: l’éponge siliconée et biseautée de Korobelnik. Bulletin de la Société belge d’ophtalmologie, 287, 73-75. https://hdl.handle.net/2078.5/132994 (Original work published 2003)