Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at sqrt(s) = 7 TeV

CMS;Basegmez, Suzan;Beluffi, Camille;Bruno, Giacomo;Bethani, Agni;et.al.
(2013) Journal of Instrumentation — Vol. 8, p. P09009 (2013)

Files

13062016.pdf
  • Open Access
  • Adobe PDF
  • 3.12 MB

Details

Authors
  • CMSUCLouvain
    Author
  • Basegmez, SuzanUCLouvain
    Author
  • Beluffi, CamilleUCLouvain
    Author
  • Author
  • Castello, RobertoUCLouvain
    Author
  • Caudron, AdrienUCLouvain
    Author
  • Ceard, LudivineUCLouvain
    Author
  • Author
  • Du Pree, TristanUCLouvain
    Author
  • Favart, DenisUCLouvain
    Author
  • Forthomme, LaurentUCLouvain
    Author
  • Author
  • Hollar, JonathanUCLouvain
    Author
  • Author
  • Liao, JunhuiUCLouvain
    Author
  • Militaru, OtiliaUCLouvain
    Author
  • Nuttens, ClaudeUCLouvain
    Author
  • Pagano, DavideUCLouvain
    Author
  • Pin, ArnaudUCLouvain
    Author
  • Piotrzkowski, KrzysztofUCLouvain
    Author
  • Popov, AndreyUCLouvain
    Author
  • Selvaggi, MicheleUCLouvain
    Author
  • Vizan Garcia, Jesús ManuelUCLouvain
    Author
  • Bethani, Agniorcid-logoUCLouvain
    Author
  • et. al.
Show more
Abstract
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity abs(eta)<0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Z to e+e- decays to a precision of 0.4% in the barrel and 0.8% in the endcaps.
Affiliations

Citations

CMS, Basegmez, S., Beluffi, C., Bruno, G., Castello, R., Caudron, A., Ceard, L., Delaere, C., Du Pree, T., Favart, D., Forthomme, L., Giammanco, A., Hollar, J., Lemaitre, V., Liao, J., Militaru, O., Nuttens, C., Pagano, D., Pin, A., et al. (2013). Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at sqrt(s) = 7 TeV. Journal of Instrumentation, 8, P09009. https://doi.org/10.1088/1748-0221/8/09/P09009 (Original work published 2013)