Quantification of 8 HIV-Protease Inhibitors and 2 Nonnucleoside Reverse Transcriptase Inhibitors by Ultra-Performance Liquid Chromatography with Diode Array Detection.

Elens, Laure;Veriter, Sophie;Di Fazio, Vincent;Vanbinst, Roger;Haufroid, Vincent;et.al.
(2008) Clinical Chemistry : international journal of molecular diagnostics and laboratory medicine — Vol. 55, n° 1, p. 170-174 (2009)

Files

20027.pdf
  • Restricted Access
  • Adobe PDF
  • 226.83 KB

Details

Authors
  • Elens, LaureUCLouvain
    Author
  • Veriter, SophieUCLouvain
    Author
  • Di Fazio, VincentUCLouvain
    Author
  • Vanbinst, RogerUCLouvain
    Author
  • Boesmans, DanielUCLouvain
    Author
  • Wallemacq, PierreUCLouvain
    Author
  • Author
Show more
Abstract
BACKGROUND: Most HPLC-UV methods for therapeutic drug monitoring of anti-HIV drugs have long run times, which reduce their applicability for high-throughput analysis. We developed an ultra-performance liquid chromatography (UPLC)-diode array detection method for the simultaneous quantification of the HIV-protease inhibitors (PIs) amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir, saquinavir, and tipranavir (TPV), and the nonnucleoside reverse transcriptase inhibitors (NNRTIs) efavirenz and nevirapine. METHODS: Solid-phase extraction of 1 mL plasma was performed with Waters HLB cartridges. After 3 wash steps, we eluted the drugs with methanol, evaporated the alcohol, and reconstituted the residue with 50 microL methanol. We injected a 4-microL volume into the UPLC system (Waters ACQUITY UPLC BEH C8 column maintained at 60 degrees C) and used a linear gradient of 50 mmol/L ammonium acetate and 50 mmol/L formic acid in water versus acetonitrile to achieve chromatographic separation of the drugs and internal standard (A-86093). Three wavelengths (215, 240, and 260 nm) were monitored. RESULTS: All drugs were eluted within 15 min. Calibration curves with concentrations of 0.025-10 mg/L (1.875-75 mg/L for TPV) showed coefficients of determination (r(2)) between 0.993 and 0.999. The lower limits of quantification were well below the trough concentrations reported in the literature. Inter- and intraassay CVs and the deviations between the nominal and measured concentrations were <15%. The method was validated by successful participation in an international interlaboratory QC program. CONCLUSIONS: This method allows fast and simultaneous quantification of all commercially available PIs and NNRTIs for therapeutic drug monitoring.
Affiliations

Citations

Elens, L., Veriter, S., Di Fazio, V., Vanbinst, R., Boesmans, D., Wallemacq, P., & Haufroid, V. (2008). Quantification of 8 HIV-Protease Inhibitors and 2 Nonnucleoside Reverse Transcriptase Inhibitors by Ultra-Performance Liquid Chromatography with Diode Array Detection. Clinical Chemistry : international journal of molecular diagnostics and laboratory medicine, 55(1), 170-174. https://doi.org/10.1373/clinchem.2008.108647 (Original work published 2009)