Visual Quality Control With CytoMDS a Bioconductor Package for Low Dimensional Representation of Cytometry Sample Distances

Hauchamps, Philippe;Delandre, Simon;Temmerman, Stéphane T.;Lin, Dan;Gatto, Laurent
(2025) Cytometry. Part A — Vol. 107, n° 3, p. 177-186 (2025)

Files

Visual Quality Control With CytoMDS , a Bioconductor Package for Low Dimensional Representation of Cytometry Sample Distances.pdf
  • Open Access
  • Adobe PDF
  • 12.78 MB

Details

Authors
  • Hauchamps, Philippeorcid-logoComputational Biology and Bioinformatics de Duve Institute UCLouvain Woluwe‐Saint‐Lambert Belgium
    Author
  • Delandre, Simonorcid-logoGSK Rixensart Belgium
    Author
  • Temmerman, Stéphane T.orcid-logoGSK Rixensart Belgium
    Author
  • Lin, DanGSK Rixensart Belgium
    Author
  • Author
Abstract
<jats:title>ABSTRACT</jats:title> <jats:p> Quality Control (QC) of samples is an essential preliminary step in cytometry data analysis. Notably, the identification of potential batch effects and outlying samples is paramount to avoid mistaking these effects for true biological signals in downstream analyses. However, this task can prove to be delicate and tedious, especially for datasets with dozens of samples. Here, we present <jats:italic>CytoMDS</jats:italic> , a Bioconductor package implementing a dedicated method for low‐dimensional representation of cytometry samples composed of marker expressions for up to millions of single cells. This method allows a global representation of all samples of a study, with one single point per sample, in such a way that projected distances can be visually interpreted. <jats:italic>CytoMDS</jats:italic> uses <jats:italic>Earth Mover's Distance</jats:italic> for assessing dissimilarities between multi‐dimensional distributions of marker expression and <jats:italic>Multi‐Dimensional Scaling</jats:italic> for low‐dimensional projection of distances. Some additional visualization tools, both for projection quality diagnosis and for user interpretation of the projection coordinates, are also provided in the package. We demonstrate the strengths and advantages of <jats:italic>CytoMDS</jats:italic> for QC of cytometry data on three real biological datasets, revealing the presence of low‐quality samples, batch effects, and biological signal between sample groups. </jats:p>
Affiliations

Citations

Hauchamps, P., Delandre, S., Temmerman, S. T., Lin, D., & Gatto, L. (2025). Visual Quality Control With CytoMDS a Bioconductor Package for Low Dimensional Representation of Cytometry Sample Distances. Cytometry. Part A, 107(3), 177-186. https://doi.org/10.1002/cyto.a.24921 (Original work published 2025)