Measurement of Cerebral Perfusion Indices from the Early Phase of [18F]MK6240 Dynamic Tau PET Imaging

Guehl, Nicolas J.;Dhaynaut, Maeva;Hanseeuw, Bernard;Moon, Sung-Hyun;Normandin, Marc D.;et.al.
(2023) The Journal of Nuclear Medicine — Vol. 64, n° 6, p. 968-975 (2023)

Files

Guehl2023_JNM_R1_MK6240.pdf
  • Open Access
  • Adobe PDF
  • 1.62 MB

Details

Authors
  • Guehl, Nicolas J.
    Author
  • Dhaynaut, Maeva
    Author
  • Author
  • Moon, Sung-Hyun
    Author
  • Normandin, Marc D.
    Author
Show more
Abstract
(en) 6-(fluoro-18F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([18F]MK6240) has high affinity and selectivity for hyperphosphorylated tau and readily crosses the blood-brain barrier. This study investigated whether the early phase of [18F]MK6240 can be used to provide a surrogate index of cerebral perfusion. METHODS: Forty-nine subjects who were cognitively normal (CN), had mild cognitive impairment (MCI), or had Alzheimer's disease (AD) underwent paired dynamic [18F]MK6240 and [11C]Pittsburgh compound B (PiB) PET, as well as structural MRI to obtain anatomic information. Arterial blood samples were collected in a subset of 24 subjects for [18F]MK6240 scans to derive metabolite-corrected arterial input functions. Regional time-activity curves were extracted using atlases available in the Montreal Neurologic Institute template space and using FreeSurfer. The early phase of brain time-activity curves was analyzed using a 1-tissue-compartment model to obtain a robust estimate of the rate of transfer from plasma to brain tissue, K 1 (mL⋅cm-3⋅min-1), and the simplified reference tissue model 2 was investigated for noninvasive estimation of the relative delivery rate, R 1 (unitless). A head-to-head comparison with R 1 derived from [11C]PiB scans was performed. Grouped differences in R 1 were evaluated among CN, MCI, and AD subjects. RESULTS: Regional K 1 values suggested a relatively high extraction fraction. R 1 estimated noninvasively from simplified reference tissue model 2 agreed well with R 1 calculated indirectly from the blood-based compartment modeling (r = 0.99; mean difference, 0.024 ± 0.027), suggesting that robust estimates were obtained. R 1 measurements obtained with [18F]MK6240 correlated strongly and overall agreed well with those obtained from [11C]PiB (r = 0.93; mean difference, -0.001 ± 0.068). Statistically significant differences were observed in regional R 1 measurements among CN, MCI, and AD subjects, notably in the temporal and parietal cortices. CONCLUSION: Our results provide evidence that the early phase of [18F]MK6240 images may be used to derive a useful index of cerebral perfusion. The early and late phases of a [18F]MK6240 dynamic acquisition may thus offer complementary information about the pathophysiologic mechanisms of the disease.
Affiliations

Citations

Guehl, N. J., Dhaynaut, M., Hanseeuw, B., Moon, S.-H., Lois, C., Thibault, E., Fu, J. F., Price, J. C., Johnson, K. A., El Fakhri, G., & Normandin, M. D. (2023). Measurement of Cerebral Perfusion Indices from the Early Phase of [18F]MK6240 Dynamic Tau PET Imaging. The Journal of Nuclear Medicine, 64(6), 968-975. https://doi.org/10.2967/jnumed.122.265072 (Original work published 2023)