Measurement of Neutron Kerma Factors for Carbon and A-150 Plastic At Neutron Energies of 26.3 Mev and 37.8 Mev

Schuhmacher, H.;Brede, HJ.;Henneck, R.;Kunz, A.;Schrewe, UJ.;et.al.
(1992) Physics in Medicine and Biology — Vol. 37, n° 6, p. 1265-1281 (1992)

Files

No attached file found for this publication.

Details

Authors
  • Schuhmacher, H.
    Author
  • Brede, HJ.
    Author
  • Henneck, R.
    Author
  • Kunz, A.
    Author
  • Meulders, Jean-PierreUCLouvain
    Author
  • Schrewe, UJ.
    Author
Show more
Abstract
Kerma factors for carbon and A-150 tissue equivalent plastic were determined in two nearly monoenergetic neutron beams. Kerma was measured with low pressure proportional counters (PCs) with walls made of graphite and A-150 plastic. The neutron fluence was measured with a proton recoil telescope. The corrections for the kerma contributions from low energy neutrons in the beams were determined by time-of-flight measurements with an NE213 scintillation detector and with the Pcs. For neutron energies of (26.3+/-2.9) MeV and (37.8+/-2.5) MeV the kerma factors for carbon were (35.5+/-3.0) pGy cm2 and (42.6+/-3.9) pGy cm2, respectively, and for A-150 they were (75.6+/-5.4) pGy cm2 and (79.0+/-5.6) pGy cm2. At these energies the kerma factor ratio for ICRU muscle tissue to A-150 calculated on the basis of the new kerma factors, is 0.93.
Affiliations

Citations

Schuhmacher, H., Brede, HJ., Henneck, R., Kunz, A., Meulders, J.-P., Pihet, P., & Schrewe, UJ. (1992). Measurement of Neutron Kerma Factors for Carbon and A-150 Plastic At Neutron Energies of 26.3 Mev and 37.8 Mev. Physics in Medicine and Biology, 37(6), 1265-1281. https://doi.org/10.1088/0031-9155/37/6/005 (Original work published 1992)