Test-retest reliability of left and right ventricular systolic function by new and conventional echocardiographic and cardiac magnetic resonance parameters.

Houard, Laura;Militaru, Sebastian;Tanaka, Kaoru;Pasquet, Agnes;Gerber, Bernhard;et.al.
(2021) European heart journal. Cardiovascular Imaging — Vol. 20, n° 1, p. 2047-2412 (2021)

Files

EJECHOjeaa206_AU.pdf
  • Open Access
  • Adobe PDF
  • 847.38 KB

Details

Authors
Show more
Abstract
(en) AIMS: Reproducible evaluation of left (LV) and right ventricular (RV) function is crucial for clinical decision-making and risk stratification. We evaluated whether speckle-tracking echocardiography (STE) and cardiac magnetic resonance feature-tracking (cMR-FT) global longitudinal (GLS) and circumferential strains allow better test-retest reproducibility of LV and RV systolic function than conventional cMR and echocardiographic parameters. METHODS AND RESULTS: Thirty healthy volunteers and 20 chronic heart failure patients underwent cMR and STE twice on separate days to evaluate test-retest coefficient of variation (CV), intraclass correlation coefficient (ICC) and estimated sample sizes for significant changes in LV and RV function. Among LV parameters, cMR-left ventricular ejection fraction (LVEF) had the highest reproducibility (CV = 6.7%, ICC = 0.98), significantly better than cMR-FT-GLS (CV = 15.1%, ICC = 0.84), global circumferential strains (CV = 11.5%, ICC = 0.94) and echocardiographic LVEF (CV = 11.3%, ICC = 0.93). STE-LV-GLS (CV = 8.9%, ICC = 0.94) had significantly better reproducibility than cMR-FT-LV-GLS. Among RV parameters, STE-RV-GLS (CV = 7.3%, ICC = 0.93) had significantly better CV than cMR-right ventricular ejection fraction (RVEF) (CV = 13%, ICC = 0.82). cMR-FT-RV-GLS (CV = 43%, ICC = 0.39) performed poorly with significantly lower reproducibility than all other RV parameters. Owing to their superior interstudy reproducibility, cMR-LVEF (n = 12), cMR-RVEF (n = 41), STE-LV-GLS and STE-RV-GLS (both n = 14) were the parameters allowing the lowest calculated sample sizes to detect 10% change in LV or RV systolic function. CONCLUSION: STE-LV-GLS and STE-RV-GLS showed higher test-retest reliability than other echocardiographic measurements of LV and RV function. They also allowed smaller calculated sample sizes, supporting the use of STE-LV and RV-GLS for longitudinal follow-up of LV and RV function.
Affiliations

Citations

Houard, L., Militaru, S., Tanaka, K., Pasquet, A., Vancraeynest, D., Vanoverschelde, J.-L., Pouleur, A.-C., & Gerber, B. (2021). Test-retest reliability of left and right ventricular systolic function by new and conventional echocardiographic and cardiac magnetic resonance parameters. European heart journal. Cardiovascular Imaging, 20(1), 2047-2412. https://doi.org/10.1093/ehjci/jeaa206 (Original work published 2021)