Method, safety, and outcomes of persistent AF ablation without a circular mapping catheter: 3 years experience of a Belgian Tertiary Centre.

Robaye, Benoît;Deceuninck, Olivier;Blommaert, Dominique;Godeaux, Véronique;Xhaet, Olivier;et.al.
(2024) Acta Cardiologica : an international journal of cardiology — Vol. 79, n° 5, p. 591-598 (2024)

Files

RobayeBActaCardiol2024.pdf
  • Open Access
  • Adobe PDF
  • 1.8 MB

Details

Authors
  • Robaye, Benoîtorcid-logoUCLouvain
    Author
  • Deceuninck, OlivierUCLouvain
    Author
  • Blommaert, DominiqueUCLouvain
    Author
  • Godeaux, VéroniqueUCLouvain
    Author
  • Dormal, Fabienorcid-logoUCLouvain
    Author
  • Collet, BenoîtUCLouvain
    Author
  • Ballant, ElisabethUCLouvain
    Author
  • Huys, FlorenceUCLouvain
    Author
  • Purnode, PhilippeUCLouvain
    Author
  • Author
Show more
Abstract
(en) BACKGROUND: We aimed to share our methods and experience of persistent AF ablation without a circular mapping catheter (CMC), thereby avoiding femoral venous and transseptal punctures, decreasing the cost of the procedure, and possibly reducing the duration of the procedure and fluoroscopy time. METHODS: We report our experience with 261 persistent AF ablations performed without a CMC over the past 3 years. RESULTS: The procedures were performed with no apparent loss of efficacy or safety. Freedom from recurrence was defined as a 1-year absence of AF/atrial flutter (AFL) episodes >30 s, beyond the 3-month blanking period. At 1 year, 72% of the patients were free from arrythmias. CONCLUSIONS: Persistent AF ablation is feasible without a CMC, reducing the need for venous and transseptal punctures and the cost of the procedure. We suggest that prospective studies should aim to characterise the reduction in procedure and fluoroscopy times as a result of this technique.
Affiliations

Citations

Robaye, B., Deceuninck, O., Blommaert, D., Godeaux, V., Dormal, F., Collet, B., Ballant, E., Huys, F., Purnode, P., & Xhaet, O. (2024). Method, safety, and outcomes of persistent AF ablation without a circular mapping catheter: 3 years experience of a Belgian Tertiary Centre. Acta Cardiologica : an international journal of cardiology, 79(5), 591-598. https://doi.org/10.1080/00015385.2022.2135240 (Original work published 2024)